Marine Corrosion Solutions
www.boatcorrosion.com         (530) 926-4000

Model RE-107 - Installation and Operating Instructions

The RE-107 Reference Assembly is a rugged and durable surface mount reference cell 4 ¾"L x 2 ¾"W with ½" thru-hull penetration. The typical lifespan is 4-5 years, depending on the conditions it is exposed to. The RE-107 can be used with vessels of any hull material and should be installed using a one part polysulfide rubber sealant such as BoatLife Life Calk.

The RE-107 was the standard reference assembly used with Electro-Guard 500 Series Systems.

The replacement zinc reference electrode is the RE-100.

Note: The RE-107 is no longer in production, however replacement zinc reference electrodes are still available. In instances where the entire reference assembly needs to be replaced the proper replacement is the RE-104.

Instructions

Current Products